SAK T.E.CTechnology · Evaluation · Compliance Free domain checkCheck

Vulnerabilities / CVE-2026-135788

Critical · not yet confirmed exploited · D-Link DIR-X1860

CVE-2026-135788

D-Link DIR-X1860 critical command injection, CVSS 9.9.

A weakness has been identified in D-Link DIR-X1860 4.5.2. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/anweb. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

9.9CVSS base score: critical, the highest band
not scoredchance of exploitation in the next 30 days (EPSS)
24 Novfirst published, 2026
Not yeton CISA's exploited list, as of 25 November 2026
Vendor and productD-Link · DIR-X1860
Typecommand injection
SeverityCritical 9.9 CVSS base score
Affected versionsDIR-X1860: 4.5.2
First published24 November 2026
WeaknessOS Command Injection; Command Injection
ExploitedNot confirmed. Critical flaws in D-Link products have been exploited before: D-Link appears on CISA's exploited list.
What to do

Patch before it is exploited

Step 1

Apply the vendor fix; command injection on an exposed device is used within days of disclosure.

Step 2

Restrict the management interface to a trusted network until the fix is in.

Step 3

Review the device's logs and configuration for changes you did not make.

Is it on your estate?

Know the day it starts being used

Threat Landscape Monitoring fingerprints the software your internet-facing hosts disclose and tells you the day a vulnerability on them is confirmed exploited, with the host and the fix. The free plan covers one domain.

Questions

CVE-2026-135788 in short

Is CVE-2026-135788 being exploited?

Not confirmed as of 25 November 2026: CISA has not added it to its Known Exploited Vulnerabilities catalogue. Critical flaws in D-Link products are a frequent target, so patch before that changes; this page is updated daily.

How severe is CVE-2026-135788?

NVD rates it critical, with a CVSS base score of 9.9.

Which versions of D-Link DIR-X1860 are affected by CVE-2026-135788?

According to the CVE record: DIR-X1860: 4.5.2. Check the vendor's advisory for the fixed version.

How do I fix CVE-2026-135788?

Apply the vendor fix; command injection on an exposed device is used within days of disclosure. Restrict the management interface to a trusted network until the fix is in. Review the device's logs and configuration for changes you did not make.

Sources: NVD, the CVE record, FIRST EPSS and the CISA Known Exploited Vulnerabilities catalogue. Page compiled automatically by SAK T.L.M, the threat-intelligence tool of SAK T.E.C, on 25 November 2026.

Chat with us