Vulnerabilities / CVE-2026-135789
Critical · not yet confirmed exploited · D-Link R95CVE-2026-135789
D-Link R95 critical command injection, CVSS 9.1.
A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
| Vendor and product | D-Link · R95 |
|---|---|
| Type | command injection |
| Severity | Critical 9.1 CVSS base score |
| Affected versions | R95: 101B06 |
| First published | 24 November 2026 |
| Weakness | OS Command Injection; Command Injection |
| Exploited | Not confirmed. Critical flaws in D-Link products have been exploited before: D-Link appears on CISA's exploited list. |
Patch before it is exploited
Apply the vendor fix; command injection on an exposed device is used within days of disclosure.
Restrict the management interface to a trusted network until the fix is in.
Review the device's logs and configuration for changes you did not make.
Know the day it starts being used
Threat Landscape Monitoring fingerprints the software your internet-facing hosts disclose and tells you the day a vulnerability on them is confirmed exploited, with the host and the fix. The free plan covers one domain.
CVE-2026-135789 in short
Is CVE-2026-135789 being exploited?
Not confirmed as of 25 November 2026: CISA has not added it to its Known Exploited Vulnerabilities catalogue. Critical flaws in D-Link products are a frequent target, so patch before that changes; this page is updated daily.
How severe is CVE-2026-135789?
NVD rates it critical, with a CVSS base score of 9.1.
Which versions of D-Link R95 are affected by CVE-2026-135789?
According to the CVE record: R95: 101B06. Check the vendor's advisory for the fixed version.
How do I fix CVE-2026-135789?
Apply the vendor fix; command injection on an exposed device is used within days of disclosure. Restrict the management interface to a trusted network until the fix is in. Review the device's logs and configuration for changes you did not make.
Sources: NVD, the CVE record, FIRST EPSS and the CISA Known Exploited Vulnerabilities catalogue. Page compiled automatically by SAK T.L.M, the threat-intelligence tool of SAK T.E.C, on 25 November 2026.